Beverage-Air Cooler Not Cooling? Causes and Fixes

A Beverage-Air bar cooler that is not cooling usually has a clogged condenser, an iced coil, a stopped fan or a failed start relay. A Boston bar diagnosis.

EPA 608 CertifiedInsuredSame Day ServiceSince 2018
Call (617) 778-2904Book Online

A Beverage-Air cooler that runs but will not get cold is almost always one of five things: a condenser coil clogged with lint and soda gun mist, an evaporator iced over from door traffic, a stopped fan, a failed start relay, or a refrigerant leak. Check the dial and the doors, pull the front grille and clean the coil, then listen. If the compressor clicks every few minutes and nothing gets cold, that is a start relay, not a dead compressor, and it is a cheap repair. We service Beverage-Air bar coolers, merchandisers and direct draw units across Greater Boston, most the same day. Call (617) 778-2904.

Beverage-Air builds the equipment sitting under the bar in most of this city. Bar back coolers in the North End, glass door merchandisers in Allston convenience stores, direct draw kegerators in Southie and Fenway, reach ins in hotel bars in the Seaport. The units are mechanically straightforward, which is good news: most of what goes wrong is serviceable, and a surprising share of it is not even a repair, it is maintenance nobody was told to do.

What makes a Boston bar cooler different from the same unit in a warehouse is the air it breathes. A bar back cooler pulls air through a grille at ankle height, in the well, roughly two feet from a soda gun and a set of taps. That air is warm, it is humid, and it carries a fine mist of sugar. Sugar makes dust stick. On the same unit in a dry stockroom the condenser needs cleaning twice a year. Behind a Boston bar it needs cleaning monthly, and almost nobody does it.

Start with the dial, the doors and the load

Before you touch a tool, rule out the free causes.

Many Beverage-Air bar coolers use a mechanical dial thermostat behind the front grille. It sits at knee height in a space where kegs get dragged and cases get shoved, and it gets knocked. Confirm it is set between 34 and 38 degrees and has not been bumped to a warmer setting or to off. Newer merchandisers and reach ins use an electronic controller instead, which will show a code such as E1 or P1 for a probe fault.

Then the doors. Sliding doors on a bar back need to actually close, and on a Friday night they often do not, because the track is full of bottle caps and lime wedges. Swing doors need a gasket that still seals.

And the load. A cooler that was just packed with four cases of warm beer at 4pm is not broken at 5pm. It is working. Give it time.

Beverage-Air not cooling: check in this order1Dial setting, doors and what was just loadedThe dial sits at knee height in the well and gets knocked constantly.2Pull the front grille and clean the condenser coilNumber one cause behind a bar. Syrup mist glues dust to the fins.3Look inside for ice on the evaporatorIce means a door, a gasket or a defrost fault, not a weak compressor.4Listen for both fans with the doors shutOne inside on the coil, one in the grille. Cheap part, total failure.5Clicking every few minutes? That is the start relayDo not leave power on. See the next graphic for why.6Clean, no ice, fans running, still warm: call a technicianRefrigerant leak or a failing compressor. Gauges required.Steps 1 to 4 are staff tasks. Steps 5 and 6 are technician work, and step 5 is usually cheap.
Most Beverage-Air calls we take in Boston end at step two.

The condenser coil, and why Boston bars are worse

The condenser is how the unit throws heat away. On a Beverage-Air bar cooler it sits behind the front grille, down at floor level, with a fan pulling air through it.

Behind a bar, that coil is not just collecting dust. It is collecting dust bonded to a film of sugar from the soda gun and beer mist from the taps. That mat is not going to fall off with a wipe. Once it is thick enough the compressor cannot reject heat, so it runs constantly, the box climbs, and the bartender tells you the cooler is dying. It is not dying, it is smothered.

How to do it properly:

Monthly in a bar. Put it on the closing checklist for the first of the month and it will get done.

Ice on the evaporator

Open the cooler and look at the coil behind the interior panel. If it is furred with frost, that is your answer. A blocked coil cannot move air, so the compressor runs and the box stays warm while the coil itself is freezing.

Ice is a symptom, not a cause. Something is letting humid air in: a sliding door that does not seat because the track is dirty, a torn gasket, a door propped during a rush, or a defrost fault on models that have one. Defrost the unit fully with the power off, then fix the door or the gasket, or the ice comes straight back.

The fans

There are two, and they fail differently.

The evaporator fan is inside. If it stops, the coil gets cold and the cabinet does not, because nothing is moving that cold around. The compressor sounds fine, so this gets misdiagnosed constantly.

The condenser fan is in the grille. If it stops, the compressor overheats and trips its own overload, so the unit cools for a while, quits, comes back, quits again.

Both are inexpensive parts and both are usually in stock on the van.

The clicking compressor, and why it matters that you stop

This is the single most useful thing on this page.

A Beverage-Air that clicks every two to five minutes, maybe with a brief hum, and never gets cold, is showing you a classic failed start relay. It is common enough on direct draw and bar cooler compressors that an experienced technician hears it down the phone.

What the click every few minutes actually isCompressor triesto startRelay has failed,motor cannot turnCurrent spikes tolocked rotorOverload tripsYou hear the clickThen the overload resets and the whole cycle repeats every 2 to 5 minutes.Leave power on overnight and this repeats hundreds of times. That is what kills the compressor.A clicking unit is usually a cheap start component. Left running, it becomes a compressor.
The relay is the cheap part. The damage comes from leaving it trying.

So the practical instruction is short: if it is clicking and not cooling, switch it off and move the product. Every locked rotor attempt dumps heat into the windings. A relay is a small part. A compressor is a decision about whether to keep the unit.

Two other things produce the same click and are worth ruling out. A compressor that is genuinely seized will click with a good relay. And low supply voltage will do it too, which in Boston is not rare: an old bar building with the cooler sharing a circuit with a blender, a POS terminal and an under bar glass washer, or running off an extension cord that should not be there. A technician checks voltage before condemning anything.

Gaskets and sliding door tracks

Routine wear, constantly ignored. Sliding doors seal only if the track is clean, and behind a bar the track collects caps, straws, fruit and broken glass. Run a finger along it. Swing door gaskets are snap in and cheap, and a gasket that no longer grips paper is a gasket that is costing you cold air every hour the bar is open.

Refrigerant, and a warning about newer units

If the coil is clean, the fans run, there is no ice and the compressor runs steadily without clicking, but the box still will not hold temperature, the system is low on refrigerant from a leak or the compressor is worn. That needs gauges.

One thing to know before anyone opens a newer Beverage-Air: most current self contained models use R-290, which is propane. It is efficient and the charge is small, but it is flammable and it is labelled as such on the cabinet. Sealed system work on an R-290 unit needs a technician equipped for flammable refrigerants and no ignition source anywhere near it. Older units, roughly pre 2015, are typically R-134a in coolers and R-404A in freezers. The rating plate inside the cabinet tells you which you have.

Check the warranty before you book anyone

Beverage-Air’s standard coverage on most bar coolers, merchandisers and direct draw units is one year parts and labor with five years on the compressor, and some series run two years on parts and labor. Terms vary by model and purchase date, and warranty work goes through their authorized agents.

So if the unit is newer, get the model and serial off the rating plate and check before you call an independent company. We would rather tell you that than take the job.

One caution worth knowing: a manufacturer can decline a compressor claim where the failure traces to a filthy condenser or bad voltage. Keeping a simple record of monthly coil cleanings is not busywork, it is what protects a five year compressor warranty.

Frequently asked

Why is my Beverage-Air bar cooler running but not cold?

Start with the dial, because on a bar back cooler it sits at knee height in the well and gets knocked to a warmer setting or to off more often than anyone expects, and confirm the doors close and seal. Then clean the condenser coil behind the front grille. Behind a bar it clogs with lint bonded to soda gun syrup and beer mist, which stops the compressor rejecting heat, so it runs constantly without cooling. Next look inside for ice on the evaporator coil, which blocks airflow, and defrost it fully. Confirm both fans run with the doors closed, the one inside on the coil and the one in the grille. If the compressor clicks every few minutes the start relay has failed. If everything checks out and it still will not cool, it is a refrigerant leak or a failing compressor and needs a technician.

Why does my Beverage-Air click but never start cooling?

A click every two to five minutes with a short hum and no cooling is the signature of a failed start relay, and it is common on Beverage-Air direct draw and bar cooler compressors. The relay and capacitor give the compressor the torque to begin turning. When the relay fails the motor cannot turn, current spikes to locked rotor, the overload protector trips with an audible click, then resets a few minutes later and the whole thing repeats. The same symptom appears when a compressor is genuinely seized, or when supply voltage is low from an overloaded circuit or an extension cord, which is worth checking in older Boston bar buildings. Switch the unit off rather than leaving it trying, because repeated locked rotor starts overheat the windings and turn a cheap relay job into a compressor replacement.

How often should a bar clean the condenser on a Beverage-Air?

Monthly in a working bar, which is more often than the manual implies, and the reason is specific to the environment. The condenser sits behind a grille at floor level within a couple of feet of soda guns and taps, so it pulls in warm humid air carrying a fine mist of sugar. That mist bonds dust to the fins into a mat that a wipe will not shift. Kill power, remove the grille, vacuum the coil face with a brush head, work a fin comb along the fins rather than across them, and use a foaming coil cleaner for the sticky layer, keeping it away from the fan motor and electrical box. Vacuum the fan blades and compartment floor while you are there. Putting it on the first of the month closing checklist is the only version of this that actually happens.

What refrigerant does a Beverage-Air cooler use?

Most current Beverage-Air self contained bar coolers, merchandisers, direct draw units and reach ins use R-290, which is refrigerant grade propane, with a small charge per circuit and a flammable refrigerant label on the cabinet. R-290 is efficient and has a very low global warming potential, which is why it is now standard. Units made before roughly the middle of the 2010s generally use R-134a in coolers and R-404A in freezers. The rating plate inside the cabinet or on the back panel states the refrigerant and the charge. Fans, relays, gaskets, thermostats and probes are serviced the same way whatever the refrigerant, but any sealed system work on an R-290 unit, including a leak repair or compressor replacement, requires a technician equipped for flammable refrigerants with no ignition source nearby.

Is my Beverage-Air still under warranty?

Standard coverage on most bar coolers, merchandisers, direct draw units and reach ins is one year on parts and labor with five years on the compressor, and some series carry two years parts and labor. The exact terms depend on model and purchase date, and warranty service runs through Beverage-Air’s authorized agents rather than any independent company. Get the model and serial number from the rating plate and check before booking an outside technician on a newer unit. Worth knowing: a manufacturer can decline a compressor claim where the failure traces back to a clogged condenser or improper voltage, so keeping a record of monthly coil cleanings and the invoice is what protects that five year compressor coverage.

The cooler quits and restarts every hour. What is that?

Cooling for a while and then quitting, then coming back, usually points at the condenser fan rather than the compressor. When that fan stops, the compressor has no way to shed heat, so it runs until its internal overload trips, rests, cools, and starts again. You get a box that is cold in the morning and warm by mid service. The same cycling pattern comes from a condenser coil so clogged that airflow is effectively gone, which is the more common version behind a bar. Check that the fan in the grille is actually turning with the unit running, and look at the state of the coil. Both are cheap to resolve, and both quietly shorten compressor life for every week they are left.

Where to learn more

Bar cooler warm before service? We repair Beverage-Air bar backs, merchandisers, direct draw units and reach ins, plus commercial refrigeration, walk in coolers and ice machines across Boston, Cambridge, Somerville, Brookline, Newton and beyond, most the same day. EPA 608 certified. From $150 commercial diagnostic, waived with the repair. Related: reach in not cooling, the fix order, Traulsen error codes, Turbo Air error codes and Massachusetts holding temperature rules. Book online or call (617) 778-2904.